The code items behind a chimney finding, one at a time
Price the repairs
Tell us what the report flagged and where the house is. We call back to plan the visit.
Clearances: how close wood may sit
The code keeps a gap between a masonry chimney and the wood framing around it, and sets how far a mantel, trim or flooring must stay from the fireplace opening. A factory built fireplace has its own listed distances, printed on its label. Findings here usually come from the attic, where framing or insulation has been packed against the brick, or from the room, where a newer mantel was fitted too close.
The fix depends on what is too close. Insulation can be pulled back and a noncombustible barrier fitted. A mantel can be moved or trimmed. Framing that touches the chimney may need cutting back. Each is quoted as its own item after we measure.
Liners: what the flue has to be lined with
A masonry chimney needs a sound lining from the smoke chamber to the top, usually clay tile on older houses here. Cracked tiles, open joints between tiles, or missing mortar are a common finding on a camera run. They matter because heat and sparks can pass through a broken lining to the brick and, from there, toward the house framing.
Small faults in a few tiles can sometimes be repaired in place. Widespread damage usually means a new stainless liner sized to the fireplace or appliance. Liners have no set price with us; the figure depends on the height, the size and what the appliance needs, so we write it down once the camera has shown us the flue. More on our [liner installation page](/services/chimney-liner-installation).
Caps and spark arrestors
Where a spark arrestor is fitted, the code limits the size of its mesh openings and sets a minimum open area, so embers are stopped while the flue still draws. A finding here is often simple: no cap at all, a cap with rusted or torn mesh, or a screen too fine and clogged with soot.
This is the item we put first on any repair list, because it is the one that decides whether sparks can leave the house or embers can come in. A new arrestor cap is quoted after we measure.
The roof: height, metal and the cricket rule
The code sets how far a chimney must rise above the roof and above anything close by, so smoke and sparks clear the roofline. It also requires the joint between chimney and roof to be sealed with metal flashing, and on the uphill side of a chimney wider than 30 inches, a cricket to split the water. Findings here include a stack that is too short, flashing that has lifted or been patched with tar, and a wide chimney with no cricket.
Height problems are rare and usually need a mason's quote. Flashing and cricket work have set prices with us, listed below, and so does tracing and sealing a leak that has already started. Our [flashing repair page](/services/chimney-flashing-repair) covers the details.
Set prices for common code fixes
These are the fixes we price in advance. Anything else on a code report gets its own written figure once we have seen it. The cap is the exception: it is quoted after we measure.
- Water splitter on the high side of a wide stack
- $465 to $1,050
- Water splitter and new roof joint metal together
- $700 to $1,750
- Finding and sealing an active leak
- $585 to $3,500
- Retiring the wood fire for a sealed gas unit
- $2,900 to $5,850
- Camera recheck once repairs are finished
- $405
- Spark arrestor cap fitted to the flue
- Quoted after we measure
Liners, crowns, dampers, chase tops and roof metal on its own have no set price here; each gets a written figure once measured.
Questions about code findings
Which code applies to my chimney?
NFPA 211 sets the national fire standard for chimneys and venting. The California Residential Code adds the state's building rules. Inspection reports usually cite one or the other.
Is my old chimney grandfathered?
Some items built under older rules can stay as they are, but anything that lets fire or exhaust reach the house, or embers in or out, should be fixed no matter when it was built.
Could the screen go on first while the bigger work waits?
In most cases. A cap and spark screen can go on first while larger work is planned. We tell you if an item depends on another.
Will you recheck after the repairs?
Yes. A camera recheck once the work is finished gives a buyer, lender or insurer a fresh report that shows the fix.
Is a gas insert a code fix?
Sometimes. Swapping an open wood fire for a sealed gas unit can retire several wood burning findings at once, though the flue it vents through still has to be sound.
Turn the finding into a fixed chimney
Use the contact page to tell us what the report flagged. We price the set items straight away and measure for the rest.
Call (626) 557-0059